Necessary equipment : 1 multimeter
This electrical resistance measure has to be done with hydrogenerator stopped out of the water.
Step 1 : Check that hydrogenerator is connected to the boat 3-phases line.
Step 2 : Disconnect the 3 phases line at its end, close to the converter.
Step 3 : As there are 4 pins on the connector, one pin of the connector is not connected. Identify the unused pin : its shape is different.
Step 4 : On the 3 other pins used for the 3 phases signal. Measure the resistance (in Ohm) between each pair of phase : 3 phases = 3 measures.
Choose the smaller caliber available on the multimeter - Usually 200Ω -
Keep the value for each pair of phase :
- Value Phase 1 - Phase 2 :
- Value Phase 2 - Phase 3 :
- Value Phase 1 - Phase 3 :
Values should be between 1,3Ω and 2,5Ω.
=> A higher value means there is an issue on the electrical continuity between the generator and converter (damaged cable, corroded or unscrewed...).
=> A low value (<1Ω) means there is a short between 2 phases (sea water in a connector, etc).